Om vi vill ha livslängden föreltransformatorVi köper för att vara tillräckligt länge, vad ska vi göra?
First of all, appearance inspection is essential. We should regularly check the appearance of the transformer to prevent that there is no oil leakage, cracks or other obvious damage and so on. Then a good job of cleaning is necessary for longer using time. We must keep the transformer and its surroundings clean to avoid dust and debris accumulation, which may interfere with the operation of the transformer or make the Transformer är inte längre i gott skick .
Då måste vi göra ett bra jobb med temperaturövervakning . Det första är temperaturinstrumentet . Vi måste använda det för att övervaka temperaturen på transformatorn för att säkerställa att det är inom det normala arbetsområdet för att undvika överhettning och fel .}
The second is to do a good job of heat dissipation. We need to check the operation of the cooling system. For the two types of transformers, dry transformers and oil transformers, their cooling systems are somewhat different. We must treat them differently to ensure good heat dissipation of the transformer.
The next step is oil quality testing. We can analyze the oil sample and regularly sample and analyze the insulating oil to check the content of moisture, acid value and other impurities in the oil. If the oil quality does not meet the standard, we must replace the insulating oil in time. The insulating oil will not only affect the heat dissipation system but also the insulation Effekt . Betydelsen av detta arbete är självklart .
After checking the transformer oil, we also shouldn't ignore the insulation test. The insulation test, from it's name we can easy to konw the insulation includes insulation resistance test and partial discharge test. For this we should conduct insulation resistance test regularly to ensure transformer's good insulation performance, and conduct partial discharge test to monitor partial discharge and detect insulation defects in time to avoid greater förluster .
Next, we need to check the connection of the transformer regularly, including fastening the connection and corrosion detection. For Fastening the connection, it means regularly checking the connection between the cable and the terminal block to ensure that there is no looseness. Corrosion detection means checking whether there is corrosion at the joint. And if the connection is unusable due to corrosion, we must deal med det .
Similarly, load monitoring is also essential. The first is load measurement. We need to regularly measure the load of the transformer to avoid overload operation. Then there is the load balance test. We use this test to ensure that the three-phase load is balanced and prevent overload.
Slutligen måste vi också göra ett bra jobb med säkerhetsskydd . Vi måste kontrollera transformatorns skyddsanordningar, till exempel överströmsskydd och överspänningskydd . Samtidigt bör vi också formulera nödplaner för att säkerställa att de kan hanteras snabbt när ett fel inträffar .}
Om vi kan göra ovanstående åtgärder, tror jag att vår transformators livslängd kommer att ökas kraftigt .